• +852 62687107
  • info@powerstability.com
  • HongKong

Product Performance Test Report

(Improved safe and reliable high-temperature battery suitable for oil and gas exploration) Product model: ER14250SM-150

I. Specification range

This document specifies the electrical performance, specifications, quality, structure, appearance,testing methods, working performance, and product aassurance of ER14250SM-150 high-temperature batteries supplied by POWER STABILITY.

II. Product Information

Electrochemical composition Model
lithium sulfite chloride battery
ER14250SM-150

III. General electrical performance

NO. Project Characteristic Remarks
1
Model
ER14250SM-150
Half wound battery
2
Nominal voltage
3.6V
36KΩ (0.1mA) load, tested at+20°C
3
Nominal capacity
800mAh
3600 Ω (1mA) discharge,+20°C, cut-off voltage 2.0V. The capacity varies depending on the size of the load, temperature, and cutoff voltage.
4
Recommended maximum continuous current
50mA
Maintain a capacity of over 80%,+20°C, and a cut-off voltage of 2.0V. Allow for higher current,please consult our company.
5
Operating temperature range
-40°C / +150°C
Working temperatures outside of room temperature may lead to a decrease in capacity and operating voltage. Please consult our company.
6
Self discharge rate
<2%
Annual self discharge rate for storage at room temperature+20℃
7
Overall dimensions (maximum)
Φ14.25mm / (H)25.25mm
Refer to product dimension drawing
8
Standard weight
10g
------
9
Battery capacity
4.2cm3
------

IV. Product appearance and structure

Exterior Structure
No scratches, rust, deformation, leakage, or any manufacturing defects.
The internal structure of ER14250SM is semi wound. The sealing adopts glass terminal compression technology. Under standard nitrogen pressure, the leakage rate is ≤ 10-7atm.cc/sec

V. Product performance

(standard data for products stored at room temperature not exceeding+30℃ for 1 year)

NO. Project Test conditions (Temperature) Battery stored at room temperature for 1 year
1
Open circuit voltage (OCV)
(Room) +20°C±2°C
3.68V±0.05V
(High) +100°C +2°C
3.68V±0.05V
(High) +145°C±2°C
3.68V+0.05V
2
Load voltage: 330 Ω load for 3 seconds,+20℃
330 Ω load for 3 seconds
≥3.15V
3
Working voltage: 330 Ω load continuous discharge, cut-off voltage 2.0V, placed upright.
(Room) +20°C +2°C
≥3.30V
(High) +100°C±2°C
≥3.30V
(High) +145°C±2°C
≥3.30V
3
Working hours, 330 Ω load continuous discharge, cut-off voltage 2.0V, placed upright.
(Room) +20°C +2°C
≥0.60Ah (60.0h)
(High) +100°C +2°C
≥0.65Ah (65.0h)
(High) +145°C±2°C
≥0.65Ah (50.0h)
5
Nominal capacity, 3600 Ω load continuous discharge, cut-off voltage 2.0V, placed upright.
330 Ω load for 3 seconds
≥3.15V
6
Electrolyte leakage test
No leakage

VI. Safety performance and environmental testing

VI.I Environmental testing

VI.I.I Thermal cycling test

Place the battery in the experimental box and perform thefollowing cycle: increase the temperature inside the box to 70±3°C within 30 minuutes, and maintain it for 4 minutes Hours. Then lower the temperature to 20±3°C and hold for 2 hoours. Reduce the temperature to -40±33°C and hold for 4 hours. Then increase the temperature to 20 ±3°C within 30 minutes. This isa cycle, repeated 10 times.

Qualification criteria: The battery shall not leak, ignite, or Iburst.

VI.I.II Low voltage (high simulation) test

The test sample is kept at a temperature of 20±3°C and an absollute pressure of 11.6KPa(1.68psi) for 6 hours.

Qualification criteria: The battery shall not leak, ignite, or burst.

VI.I.III Heating test

Place the test sample in a gravity convection heating furnaace or a thermal cycling drying furnace for heating. Heat at at a rate of 5±2°C per minute to 145±2°C and hold for 10 minutes.

Qualification criteria: The battery shall not leak, ignite, or burst.

VI.II Mechanical performance testing

VI.II.I Free fall

According to IEC standards, each side of the battery must drop from a height of 1 meter to the cement floor twice, a total of 6 times.

Qualification criteria: The battery shall not leak, ignite, or burst.

VI.II.II Vibration test

The vibration frequency of the battery varies by 1 Hz per minutebetween 10 and 55 Hz, with a maximum of 90 minutes 100 minutes, tested on three sides.

Qualification criteria: The battery shall not leak, ignite, or burst.

VI.II.III Impact testing

Place the sample on the platform. A 5/8 inch (15.8mm) diameter iron rod is placed at the center of the battery. One A weight of 20 pounds (9.1 kilograms) fell freely from a height of 24+1 inch (610 + 25mm) onto a round rod.

Qualification criteria: The battery shall not ignite or burst.

PSY-Battery_Testing-ER14250SM-150

QUICK INQUIRY

Please enable JavaScript in your browser to complete this form.